Steel structures & PEB for the Philippines · CIF & DDP delivery Philippine projectsContact Client portal dang.victor@worldsteelgroup.com +84 902 881 833
Philippines · Steel Structures & PEB
Steel frame with seismic bracing and moment connections

Solution · Typhoon & earthquake

Steel designed for typhoons and earthquakes

The Philippines faces both every year. We design every frame for NSCP 2015 wind and seismic Zone 4 – and show you exactly which one governed.

Request a quotationExplore the solution

Sec. 207
NSCP wind design
Sec. 208
NSCP seismic design
Zone 4
Most of the archipelago
Steel moment frame

Two hazards, one frame

Steel is light, so earthquake forces stay low, and ductile, so it yields rather than snaps. But light also means wind uplift can govern the roof, purlins and anchors. A good Philippine design checks both, for your exact site, and details connections that keep their strength through repeated loading.

We choose between moment frames, braced frames and combinations based on your layout and the soil profile.

Applications

What we check

01

Basic wind speed

For your municipality and exposure.

02

Roof uplift

Purlins, fixings and anchor bolts.

03

Seismic zone & source

Including near-fault effects.

04

Soil profile

From your geotechnical report.

05

Ductile detailing

Connections that yield safely.

06

Drift limits

Protecting walls and finishes.

Codes & compliance

Designed for Philippine approval

The codes our engineers work to on Philippine projects – and the approvals your project team will obtain with our documents.

Philippines

  • NSCP 2015 Vol. 1National Structural Code of the Philippines – loads, wind (Sec. 207), seismic (Sec. 208) and steel design
  • AISC 360 / AISC 341Structural steel design and seismic provisions, as referenced by NSCP Chapter 5
  • AISI S100Cold-formed steel members – purlins, girts and eave struts
  • AWS D1.1Structural welding – procedures, welders and inspection
  • ISO 12944Corrosion protection by paint systems, by corrosivity category C2–C5
  • PD 1096 · RA 9514National Building Code and Fire Code of the Philippines (Revised IRR 2019)
Engineer of record
Plans and calculations signed and sealed by a Philippine-licensed civil or structural engineer for the building permit
Fire safety
Fire Safety Evaluation Clearance (FSEC) from the BFP before the permit; fire-resistance ratings per type of construction

Summary for orientation only – the project specification, the adopted code edition and the authority having jurisdiction govern.

Engineering

Bracing and connections

Braced bays are detailed so the brace yields before the connection, and moment connections follow prequalified details where ductility is required.

Concentrically braced steel frame
Steel roof in strong wind

Engineering

Purlins in a typhoon

Most typhoon damage starts at the edge of the roof. We tighten purlin spacing and bracing at corners and edges, where suction peaks.

FAQ

Frequently asked questions

Is all of the Philippines in seismic Zone 4?

Almost all of it; only Palawan, Sulu and Tawi-Tawi are Zone 2 under NSCP 2015. We use the zone and fault distance for your site.

What wind speed do you use?

The basic wind speed in NSCP 2015 for your location, with exposure and topography factors.

Ready to price your building?

Send the layout, the site location and your target date. We reply with a frame concept, steel tonnage and a CIF or DDP price.

Request a quotation +84 902 881 833

Delivery terms · Incoterms® 2020

Delivered on the terms you need

World Steel quotes ex-factory, free on board or delivered to your port or site. Export packing, documents and shipment from Ho Chi Minh City are part of our service.

Compare all Incoterms® 2020 →