Steel structures & PEB for the Philippines · CIF & DDP delivery Philippine projectsContact Client portal dang.victor@worldsteelgroup.com +84 902 881 833
Philippines · Steel Structures & PEB
Steel-framed hospital building with canopy

Solution · Hospitals & healthcare

Hospitals that keep working after the earthquake

Steel frames for hospitals, medical arts buildings, clinics and laboratories – designed as essential facilities to NSCP 2015, fire-rated for healthcare occupancy and ready to grow.

Request a quotationExplore the solution

I = 1.5
Essential-facility importance
NSCP 2015
Long spans
Theatres & imaging
Expandable
Floors and wings
Steel braced frame for seismic resistance

Essential facilities need essential engineering

Under NSCP 2015 a hospital is an essential facility. It is designed for larger seismic and wind forces than an ordinary building, with drift limits that protect partitions, medical gases and sensitive equipment. Steel braced and moment frames give the strength and ductility this requires with less weight on the foundations.

We work with your engineer of record and medical planners on equipment loads, vibration criteria for imaging and laboratories, and space for deep service zones above every corridor.

Applications

Healthcare buildings

01

General and specialty hospitals

Wards, theatres and diagnostics.

02

Medical arts buildings

Doctors' clinics beside the hospital.

03

Diagnostic and dialysis centres

Fast-track standalone buildings.

04

Laboratories

Vibration-controlled floors.

05

Medical schools

Teaching and simulation facilities.

06

Extensions

New floors and wings on existing campuses.

Codes & compliance

Designed for Philippine approval

The codes our engineers work to on Philippine projects – and the approvals your project team will obtain with our documents.

Philippines

  • NSCP 2015 Vol. 1National Structural Code of the Philippines – loads, wind (Sec. 207), seismic (Sec. 208) and steel design
  • AISC 360 / AISC 341Structural steel design and seismic provisions, as referenced by NSCP Chapter 5
  • AISI S100Cold-formed steel members – purlins, girts and eave struts
  • AWS D1.1Structural welding – procedures, welders and inspection
  • ISO 12944Corrosion protection by paint systems, by corrosivity category C2–C5
  • PD 1096 · RA 9514National Building Code and Fire Code of the Philippines (Revised IRR 2019)
Engineer of record
Plans and calculations signed and sealed by a Philippine-licensed civil or structural engineer for the building permit
Fire safety
Fire Safety Evaluation Clearance (FSEC) from the BFP before the permit; fire-resistance ratings per type of construction

Summary for orientation only – the project specification, the adopted code edition and the authority having jurisdiction govern.

Engineering

Growth without disruption

Hospitals change constantly. Steel frames make it practical to add floors, open new connections and carry new equipment – and much of the work can be prefabricated to keep noise and dust away from patients.

Multi-storey steel frame under construction

Delivery terms · Incoterms® 2020

Delivered on the terms you need

World Steel quotes ex-factory, free on board or delivered to your port or site. Export packing, documents and shipment from Ho Chi Minh City are part of our service.

Compare all Incoterms® 2020 →

FAQ

Frequently asked questions

Can you add floors to our existing hospital?

Where the existing structure and foundations allow it, yes. We check the building first and design a light steel extension.

What fire rating do hospital members need?

It depends on the type of construction and the Fire Code requirements for health facilities; we schedule ratings per member with your fire engineer.

Ready to price your building?

Send the layout, the site location and your target date. We reply with a frame concept, steel tonnage and a CIF or DDP price.